HYPOTHEEKINDEX.EU ≡ Pulse Oximeter New Arrival Suction Machine Bomber Jackets
  • Compressor

  • Contec CMS9000 6 Parameter 12” Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG w/ Printer

Contec CMS9000 6 Parameter 12” Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG w/ Printer

$44.29 $63.33
Contec CMS9000 6 Parameter Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG w/ Printer Specifications: ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s HR: Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~ 2.0mV Precision: -0.8mv~ 0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH RESPIRATION Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. NIBP Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode SpO2 Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. PR Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher TEMP Channel: dual-channel Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC EtCO2 Method: Sidestream or Mainstream CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes. IBP Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. Accessories SpO2 test for adult fingertips (5-pin) NIBP adult cuff NIBP extension pipe ECG lead cable ECG electrode Temperature probe Power cord Physical characteristic Dimension: 319 mm(L) × 161 mm(W) × 269 mm(H) Weight: 3.6 Kg
Compressor

Compressor

  • Soundless Dental compressor
    $68.87 $119.83
  • Contec CMS9000 6 Parameter 12” Patient Monitor-SPO2,PR,NIBP,RESP,TEMP,ECG w/ Printer
    $44.29 $63.33
  • LH-1000 Oil-Free Air Compressor
    $47.07 $75.78
  • LH-500 Oil-Free Air Compressor unit-one
    $48.21 $87.74

© 2026 - HYPOTHEEKINDEX.EU